MF22-type gas masks

Oil mist penetration coefficient: not more then 0.005% at 30L/min.

Inhalation resistance: not more than 186 Pa at 30L/min.

Exhalation resistance: not more then 90 Pa at 30L/min.

Weight: Complete set of mask app. 1100 grams.

Storage life: more then 10 years.

Description

Product Category:Military and Police gas masks

Product Description:Type MF22 Gas Mask is a kind of respiratory 

protective equipment designed for the military joint service. 

It is used to provide effective protection to the wearer’s face, 

eye, and respiratory organs against the toxic agents.

Type MF22 Gas Masks

1   Application and Features

Type MF22 Gas Mask is a kind of respiratory protective equipment 

designed for the military joint service. It is used to provide effective 

protection to the wearer’s face, eye, and respiratory organs 

against the toxic agents and radioactivity when suffering the 

chemical attack or acting on duty in the toxic, radioactive 

contaminated areas. But it is forbidden for the masks to 

be used in the environments of anoxic and 

carbon monoxide.

 

The face seal of the mask is treated specially an arc shape with 

periphery turned inwards, in order to wear comfortable and 

leak-free fit.  It has an excellent feature of the resistance to the 

penetration of agents and the decontamination. There is a cam 

shape around the outside edge of the face blank, which can be 

matched with a hood.

 

Six head harnesses can be adjusted at random, but the 

flexibility of the face piece must be suitable. Two rounded 

eyepieces can be matched with the optical equipment. The lenses 

are manufactured from optical plastic and surface-treated with a 

wearable coating, and provide excellent optical 

properties and good abrasion and shock resistance.

 

The communication system of masks are designed in a form of 

double voicemitters, the main voicemitter, exhalation valve, and 

drinking device are designed as one body. The exhalation valve is 

easy to remove so that it can be cleaned. The drinking device can 

be operated easily. The main voicemitter has less loss of voice 

transferring.The aide voicemitter is fit on the right cheek of the 

masks, and can be matched with communication equipments.The 

nosecup with two inhalation valves is fit in the face piece, and 

has a good transparency.The canister is filled with impregnated 

carbon of good quality and high efficiency filter paper and can filter 

out toxic gases and particulate aerosol from the influent air except 

carbon monoxide. The canister has a low resistance, lightweight 

and service life.

 

2      Technical Specification

2.1   Gas Life for Sarin: not less than 110 minutes at 30 L/min,

 4mg/L conditions.

2.2   Gas Life for Cyanogen chloride: not less than 30 minutes at 

30 L/min, 4mg/L, 80-80% RH conditions.

2.3   Oil mist penetration coefficient: not more then 0.005% at 

30L/min.

2.4   Inhalation resistance: not more than 186 Pa at 30L/min.

2.5   Exhalation resistance: not more then 90 Pa at 30L/min.

2.6   Visual field: total not less than 60%, binocular visual field 

not less than 15%.

2.7    Weight: Complete set of mask app. 1100 grams.

2.8   Storage life: more then 10 years. 

 

3      USAGE AND MAINTENANCE  

 3.1   The MF22 Gas Mask is divided into three sizes 

such as small, medium and large on the left lower part 

of the faceblank respectively with one of three numbers: 

1(small), 2(medium) or 3(large). The users can choose a 

suitable mask according to their head shape. The method 

is to measure the distances in the horizontal central line 

between the wearer’s chin and the central point between 

the inner canthus, then the size of masks can be 

determined according to the actual data of 1, 2, 3.

 

3.2  After the mask has being worn, plug up the inlet of a 

canister with a hand, then, make an inspiration hard, if there 

is any leakage on the mask, a mask, which is one size smaller, 

should be instead of it.

 

3.3   Usage of drinking device: The cap of a special canteen 

should be screwed previously in the canteen. When the 

wearer needs to drink water, one hand should keep the mask 

steadily, the middle finger of another hand should take the 

plug of drinking tube out, then turn the handle anticlockwise 

to 180°with right hand, grip a drinking tube inside the

facepeice with mouth, hold the canteen with right hand, and

 pull out the plug of the canteen, insert the plug of drinking 

tube inside the cap of the canteen with left hand. Finally, raise 

up the inverted canteen near the facepiece, the height of 

canteen should be kept at the level of eyes, pay attention to

 blow the air while drinking water, in order to keep the water 

flowing. But the canteen must not raised too high, so as to avoid

 breaking off of the connecter.  After the drinking has finished,the 

drinking device should be resumed to its original state by means 

of the reverse process.

 

3.4   The mask is equipped with a resistance simulator, which is 

used to instead of a canister in the period of training. But the 

simulator must be removed and canister should be 

assembled during the operation of poisoning and in the warfare.

3.5   The complete mask, particularly the lenses and the 

exhalation valve, should be kept clean. If necessary the 

facepiece can be washed with clear water.

 

3.6   The canister can decrease its adsorption capacity for 

toxic gases if it has absorbed the moisture. The closure cap 

and the plug should usually be attached to the canister to 

prevent the ingress of moisture.

 

3.7   The gas masks should be stored in a cool dry place. 

If the masks are not in use for a longer period of time, 

a support should be placed in each faceblank to prevent 

the deformation. The facepiece must not be contacted 

with organic solvent.

MF22-type gas masks-XINXING